Process to Signal For iPad 1.0

Status Instruments’ free App for converting a process signal value, in any engineering unit, into a control signal in milli amps, milli volts, or volts.
For use in temperature measurement, process control, and signal conditioning


The input engineering range and output signal range are entered into the calculator.


Typical use would be for a control or alarm system monitoring the temperature in a vessel. A temperature transmitter would be used to generate a mA signal to represent °C.

Example
Input range in engineering units (0 to 100)°C ; output signal range (4 to 20) mA [sometimes given as 4-20mA]

A point input value can entered in °C and the corresponding output signal value in mA calculated.

An output signal value in mA can entered and the corresponding input temperature in °C calculated

Typical engineering units
inH2, inHg, ftH2O, mmH2O, mmHg, psi, bars, mbar, g/sqcm, kg/sqcm, Pa, KPa, Torr, Atmosph, Cuft/min , gal/min, L/min, Impgal/min, Cum/h, ft/s, m/s, gals/s, MMgal/d, L/s, ML/d, Cuft/s, Cuft/d, Cum/s, Cum/d, Impgal/h, Impgal/d, Deg C, Deg F, Deg R, Kelvin, Mv, ohms, Hz, mA, gal, L, Impgal, Cum, Ft, M, Bbl, In, Cm, Mm, Min, S, H, D, cSt, cP, uMho, %, V, pH, g, kg, Met Ton, Lb, STon, LTon, mS/cm, uS/cm,N, Nm, g/s, g/min, g/h, kg/s, kg/min,kg/h,kg/d, Met Ton/min, Met Ton/h, Met Ton/d, lb/s, lb/min, lb/h, lb/d, STon/min, STon/h, STon/d, LTon/h, LTon/d, Datherm, SGU, g/Cucm, kg/Cum, lb/gal, lb/Cuft, g/mL, kg/L, g/L, lb/Cuin, STon/Cutd, degTwad, degBrix, degBaum hv, degBaum lt, degAPI, % sol-wt, % sol-vol, degBall, proof/vol, proof/mass, bush, Cuyd, Cuft, Cuin, in/s, in/min, ft/min, deg/s, rev/s, rpm, m/h, NmlCum/h, NmlL/h, StdCuft/min, bbl(liq), Cuft/hr, Cum/min, bbl/s, bbl/m, bbl/h, bbl/d, gal/h, impgal/s, L/h, Ppm, Mcal/h, Mj/h, Btu/h, Deg, Rad, inH2O @ 60°C, ug/L, ug/Cum,%Cs, Vol%, % Stm Quad, ft.in 16, Cuft/Lb, pF, mL/L, uL/L, % plato, % LEL, Mcal, KO, MJ, Btu, NmlCum, Nm/L, StdCuft, Ppb, gal/d, hL, MPa, inH2O @ 4°C, mmH2O @ 4°C, & uV.


Note: the values represent ideals, no tolerances have been applied and no allowances for input source errors, or output measurement equipment errors have been used.

Celkové hodnocení

Průměr hodnocení
3

Pro hodnocení programu se prosím nejprve přihlaste

Přejít do App Store

Souhrnné informace o Process to Signal For iPad

  • Verze programu

    1.0
  • Autor

  • Potřeba instalace

    ano
  • Velikost souboru

    11,16 MB
  • Systémové požadavky

    Aplikace pro: iPad
  • Jazyk

    • Angličtina
  • Staženo

    0× celkem
    0× tento měsíc
  • Poslední aktualizace

    31. 3. 2017

Něco jsme propásli?

Dejte nám vědět. Upozornit redakci Stahuj
Velice děkujeme za Vaše podněty